Wednesday, October 10, 2018

Din Rail Switching Mode PS air conditioners work in turn and set the temperature?

With the continuous development of network information technology, the environmental parameters in the computer room where the server is stored are also becoming more and more important. Some small and medium-sized computer rooms keep the temperature inside the equipment room within a certain range. Not only one air conditioner is installed, but also a spare air conditioner is stored. The purpose is to prevent malfunction of the air conditioner in operation or other reasons. It is necessary to turn on the backup air conditioner. However, it is impossible for the computer room management personnel to stay in the computer room for 24 hours. In order to reduce the burden on the computer room management personnel, the air conditioner intelligent switcher can solve this problem well.
The air conditioner switch can control two air conditioners at the same time to realize functions such as air conditioner caller self-start, timed temperature control switch, failover, and fault alarm. Applicable to computer room, outdoor base station, archives, warehouse and other places. Its principle of using infrared code to switch air conditioners makes the device compatible with all brands of air conditioners on the market.
First, the air conditioner switch concept
The air conditioner dual-machine switcher is a kind of intelligent air-conditioner controller, which can detect and control the running state of the air-conditioner, and control according to the preset air-conditioner operation, shutdown and combined behavior, with automatic call start function, cycle switching, temperature control, Timing control, relay output and other functions. The purpose of protecting equipment, saving energy and reducing consumption, improving the efficiency of computer room management and extending the service life of air conditioners has been achieved. This product is widely used in civil, small and medium-sized computer rooms, communication stations, UPS machine rooms in all types of cabinets. Mainly used for switching control of two air conditioners.
Second, the advantages and Din Rail Switching Mode PS
Industrial design
It adopts industrial grade design and built-in watchdog circuit to ensure the normal operation of the equipment.
32-bit ARM processor
With a 32-bit ARM processor, it features fast processing and stable performance.
User-friendly interface
The display part adopts a TFT color liquid crystal screen, and has a user-friendly operation interface, and the operation is simple.
Brand optional, temperature optional
Built-in thousands of infrared codes, supporting up to 30 air-conditioning brands, including Midea, Gree, Oaks, Island, Skyworth, Chunlan, Daikin, Galanz, Haier, Hisense, Hualing, Kelon, Likal, Hitachi, Mitsubishi, Mitsubishi Electric, Mitsubishi Heavy Industries, Samsung, Panasonic, Sharp, Duckling, Electrolux, Sakura, Chigo, Changhong, Wellcome, TCL, LG, etc., support more than 95% of air conditioners on the market, and can set the boot temperature.
Universal infrared code learning function
Some uncommon air-conditioning brands that do not support built-in infrared codes can use the infrared code learning function to control air conditioners.
Call self-start
When the air conditioner encounters a power outage and then calls, the air conditioner shutdown cannot be automatically started, and manual startup is required, which brings great trouble to the management. When the power is detected and the call is detected, the infrared signal can be automatically sent to turn on the air conditioner without human control. The call start time can be customized.
Cycle switching
Single or two air conditioning cycle switching can be set, and the cycle switching time can be customized to support 1 minute to 99 hours. Cycle switching is often used to alternate between two air conditioners to improve air conditioning life.
Real-time temperature monitoring and control
It can monitor the ambient temperature in real time, and can be customized. When the ambient temperature exceeds or falls below the custom threshold temperature, the air conditioner turns on or off, and the cycle switching function is turned off until the temperature returns to normal.
Timing control
With RTC real-time clock, up to 5 timed tasks can be set to automatically control the air conditioner at a certain time. The timing mode can be set to single, daily or weekly.
One relay output
It can be customized to turn on or off the relay when the temperature is too high, too low or normal. The Din Rail Switching Mode output is recommended to connect the sound and light alarm to achieve high and low temperature warning function.
Third, technical parameters
 2-way infrared interface
Connection method: Plug and play
Control distance: <5 meters
1 relay output
Contact capacity: (AC) 250 V @ 3 A
Contact capacity: (DC) 30 V @ 3 A
On time (typical): 3 ms
Disconnect time (typical): 1 ms
Insulation resistance: minimum 1000 MΩ (500VDC)
Appearance parameters: 140*100*32mm
Power requirements: DC: +9V ~ +12VDC
Power consumption: 1.9W @12VDC
Mechanical characteristics: ABS plastic housing, standard DIN rail mounting
Environmental characteristics
Working temperature: -10 ~ 60 °C
Storage temperature: -20 ~ 85 °C
Humidity: 5 ~ 95%, no condensation
Fourth, the application area
Industrial site control
Computer room monitoring
Intelligent building
Power communication
Warehousing and monitoring
Electronic product manufacturing
Food machine beverage industry
Five, wiring method
Content source:http://www.wattconenergy.com/

Din Rail Switching Mode air conditioners work in turn and set the temperature?

With the continuous development of network information technology, the environmental parameters in the computer room where the server is stored are also becoming more and more important. Some small and medium-sized computer rooms keep the temperature inside the equipment room within a certain range. Not only one air conditioner is installed, but also a spare air conditioner is stored. The purpose is to prevent malfunction of the air conditioner in operation or other reasons. It is necessary to turn on the backup air conditioner. However, it is impossible for the computer room management personnel to stay in the computer room for 24 hours. In order to reduce the burden on the computer room management personnel, the air conditioner intelligent switcher can solve this problem well.
The air conditioner switch can control two air conditioners at the same time to realize functions such as air conditioner caller self-start, timed temperature control switch, failover, and fault alarm. Applicable to computer room, outdoor base station, archives, warehouse and other places. Its principle of using infrared code to switch air conditioners makes the device compatible with all brands of air conditioners on the market.
First, the air conditioner switch concept
The air conditioner dual-machine switcher is a kind of intelligent air-conditioner controller, which can detect and control the running state of the air-conditioner, and control according to the preset air-conditioner operation, shutdown and combined behavior, with automatic call start function, cycle switching, temperature control, Timing control, relay output and other functions. The purpose of protecting equipment, saving energy and reducing consumption, improving the efficiency of computer room management and extending the service life of air conditioners has been achieved. This product is widely used in civil, small and medium-sized computer rooms, communication stations, UPS machine rooms in all types of cabinets. Mainly used for switching control of two air conditioners.
Second, the advantages and Din Rail Switching Mode
Industrial design
It adopts industrial grade design and built-in watchdog circuit to ensure the normal operation of the equipment.
32-bit ARM processor
With a 32-bit ARM processor, it features fast processing and stable performance.
User-friendly interface
The display part adopts a TFT color liquid crystal screen, and has a user-friendly operation interface, and the operation is simple.
Brand optional, temperature optional
Built-in thousands of infrared codes, supporting up to 30 air-conditioning brands, including Midea, Gree, Oaks, Island, Skyworth, Chunlan, Daikin, Galanz, Haier, Hisense, Hualing, Kelon, Likal, Hitachi, Mitsubishi, Mitsubishi Electric, Mitsubishi Heavy Industries, Samsung, Panasonic, Sharp, Duckling, Electrolux, Sakura, Chigo, Changhong, Wellcome, TCL, LG, etc., support more than 95% of air conditioners on the market, and can set the boot temperature.
Universal infrared code learning function
Some uncommon air-conditioning brands that do not support built-in infrared codes can use the infrared code learning function to control air conditioners.
Call self-start
When the air conditioner encounters a power outage and then calls, the air conditioner shutdown cannot be automatically started, and manual startup is required, which brings great trouble to the management. When the power is detected and the call is detected, the infrared signal can be automatically sent to turn on the air conditioner without human control. The call start time can be customized.
Cycle switching
Single or two air conditioning cycle switching can be set, and the cycle switching time can be customized to support 1 minute to 99 hours. Cycle switching is often used to alternate between two air conditioners to improve air conditioning life.
Real-time temperature monitoring and control
It can monitor the ambient temperature in real time, and can be customized. When the ambient temperature exceeds or falls below the custom threshold temperature, the air conditioner turns on or off, and the cycle switching function is turned off until the temperature returns to normal.
Timing control
With RTC real-time clock, up to 5 timed tasks can be set to automatically control the air conditioner at a certain time. The timing mode can be set to single, daily or weekly.
One relay output
It can be customized to turn on or off the relay when the temperature is too high, too low or normal. The Din Rail Switching Mode output is recommended to connect the sound and light alarm to achieve high and low temperature warning function.
Third, technical parameters
 2-way infrared interface
Connection method: Plug and play
Control distance: <5 meters
1 relay output
Contact capacity: (AC) 250 V @ 3 A
Contact capacity: (DC) 30 V @ 3 A
On time (typical): 3 ms
Disconnect time (typical): 1 ms
Insulation resistance: minimum 1000 MΩ (500VDC)
Appearance parameters: 140*100*32mm
Power requirements: DC: +9V ~ +12VDC
Power consumption: 1.9W @12VDC
Mechanical characteristics: ABS plastic housing, standard DIN rail mounting
Environmental characteristics
Working temperature: -10 ~ 60 °C
Storage temperature: -20 ~ 85 °C
Humidity: 5 ~ 95%, no condensation
Fourth, the application area
Industrial site control
Computer room monitoring
Intelligent building
Power communication
Warehousing and monitoring
Electronic product manufacturing
Food machine beverage industry
Five, wiring method
Content source:http://www.wattconenergy.com/

Sunday, August 26, 2018

Why AR-VR practitioners should not quote Gartner technology maturity graphs

(Aviation Network May 9, 2017) The earliest is in mid-2016 I saw a Gartner technology maturity curve from WeChat friends circle. WeChat friends who posted this information are excited to say that the latest 2016 Gartner technology maturity curve shows that VR has passed the hype period.

I am also a bit excited about this information. However, I would like to know more about the technical maturity curve of VR in the past two years, so I started searching on the Internet, but I was surprised. The following is a review of the technical maturity curve published by Gartner from 2012 to 2018.

Even vr hk disappeared on the 2018 chart. Could it be that VR is mature? Still, Gartner's 2017 chart also says that VR technology is still mature for two to five years. If you go to the leaders of VR technology in Oculus, Valve, Microsoft, Sony and other industries, I believe they will tell you that VR technology is still immature. Even this industry technology is not an evolution, but a revolutionary breakthrough.

According to the Gartner technology maturity curve, VR has already passed the hype in 2013.

Thursday, June 14, 2018

Last year, VR market is still dominated by hardware, and future AR will surpass VR

The data analysis company Super Data recently released the 2017 VR market report. This report shows that last year the global VR market was still dominated by hardware, with hardware sales accounting for 75%. Spuer Data expects XR market hardware and software revenues to reach $760 million in 2018, driven by AR/MR development and successful games. The development of smart phones will allow AR/MR to lead VR 360 by 2021.

data

In terms of software, games account for 55% of VR consumer software revenue. HTC Vive and PSVR have higher player viscosities, and mobile VR is even more dominant in number, but profits account for only 15% of VR game revenue. Bethesda's two games, "Radiation 4" and "The Elder Scrolls 5: Skyrim" won the 2017 PC VR and PSVR earnings list championships respectively. Nearly half of VR users are enterprise users, including some schools and hospitals, but their spending power is not very good.

The report also believes that mobile AR will become the main driver of revenue by 2021, about twice the revenue of VR/MR head-display software. In the short term, high-end VR headsets will still affect their popularity among consumers due to the relatively high selling prices.